What was found
DOOR 2R SLIDE ARM LT CONT FLASHES. HANDLE MOVING. VIDEO DOCUMENTATION. ACFT NEEDS FLT CHECK. ADJUSTED FLEX CONTROL ROD LOWER ROD END PER AMM. CHECK DOOR RIG AND GAPS REF MM 52-13-22 AND SWITCH REF MM 52-71-00 ACCOMPLISHED. FOUND GIRT BAR ARMING MECHANISM PARTS 390 & 400 LOOSE AT SERRATIONS DUE TO LOOSE HARDWARE. VERIFIED SAFETY & SECURITY OF DOOR 2R ARMING MECH. OPS NORMAL. NO DEFECTS NOTED. WHEN PERFORMING EMERGENCY LIGHT TEST ACCT DOOR 2R SLIDE INSTALLATION, GOT CIDS MESSAGE EMERGENCY BATTERY FWD LEFT. REPLACED FWD LEFT EMERGENCY LIGHT BATTERY. EMERGENCY LIGHT TEST CHECKED OK.