What was found
ELMS P210 PANEL THE ELECTRICAL LOAD MANAGEMENT SYSTEM (ELMS) P210 PANEL IS FAULTED SUCH THAT IT CANNOT SUPPORT AIRPLANE DISPATCH. AIMS HAS LOTS ARINC 629 COMMUNICATION WITH THE P210 PANEL. OR ONE P210 PANEL CHANNEL IS LOST AND THE OTHER FAULTED AND IS OPERATING IN A DEGRADED MODE. OR BOTH P210 PANEL CHANNELS ARE FAULTED AND A STATUS MSG01- ACTIVE CLIMB HARD; ELMS P210 - POWER MANAGEMENT PANEL - (RT) HAS NO OUTPUT ON ANY BUS. REPAIR, RERACKED P210 CARD M24403A3 AND PERFORMED MT 24-023-R3. MSG'S CLEAR FROM STATUS AND SHOW NOT ACTIVE ON THE PMAT.