What was found
POTABLE WATER INOP IN ENTIRE AIRCRAFT. HOUSTON REPORTEDLY SERVICED SYSTEM BEFORE DEPARTURE. DRAIN VALVE FROZEN IN OPEN POSITION, UNABLE TO RETAIN WATER. TRIED ACT NO HELP. REPLACED FILL VALVE (643-1474).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
POTABLE WATER INOP IN ENTIRE AIRCRAFT. HOUSTON REPORTEDLY SERVICED SYSTEM BEFORE DEPARTURE. DRAIN VALVE FROZEN IN OPEN POSITION, UNABLE TO RETAIN WATER. TRIED ACT NO HELP. REPLACED FILL VALVE (643-1474).