What was found
ELMS P110 CHANNEL ONE, BUT NOT BOTH, OF THE ELECTRICAL LOAD MANAGEMENT SYSTEM (ELMS) P110 PANEL CHANNELS ARE FAULT-DUE TO DF564 ON CHA A. SWAPED 629 CARD BETWEEN CHANNEL A AND B WITH FAULT FOLLOWS, RETURNED CARD TO ORIGINAL, REPLACED A3 CARD WITH ROBBED CARD AND ALSO REPLACED POWER SUPPLY CARD A1. STILL SHOWS POWER SUPPLY FAULT. REF FIM 24-09 TASK 804 AND AMM-24-09-00-201. CHASSIS ON STASH (BULK AREA). SECURED A3 CARD IN P110 PANEL DUE TO NOT BEING FULLY SEATED, MESSAGES CLEARED, REF MM 24-09-00. ()ABOVE SHOULD READ A2 SECURED. DUE TO DF564 ON CHA A. SWAPPED A1 AND A15 CARDS PER MM AND TESTED NORMALLY. MSG NOW NOT ACTIVE.