As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD CARGO COMP HAS DAMAGE AT STA 619. FLOOR PANEL HAS 6 INCH PIECE BROKEN OFF WITH ATT BRACKET. CENTER GUIDE ASSY IS DAMAGED AND BRACKET SHEARED OFF FROM FLOOR STRUCTURE. ACCOMPLISHED INTERIM REPAIR PER ECRA5330-04387. NEEDS NEW FLOOR PANEL AND GUIDE. FWD CARGO CENTER GUIDE ASSY AT STATION 619 MISSING. REPLACED FLOOR PANEL, BOTH SUPPORT BRACKETS FLOOR BOARD AND CENTER GUIDE.