What was found
AILERON SERVO FAULT DISPLAYED ON UPPER ECAM SCREEN. REMOVED AND REPLACED NR 2 ELAC COMPUTER. PERFORMED OPS TEST OF ELACS IAW AMM. PERFORMED AFS LAND TEST. ALL TESTS PASSED, NO FAULTS NOTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AILERON SERVO FAULT DISPLAYED ON UPPER ECAM SCREEN. REMOVED AND REPLACED NR 2 ELAC COMPUTER. PERFORMED OPS TEST OF ELACS IAW AMM. PERFORMED AFS LAND TEST. ALL TESTS PASSED, NO FAULTS NOTED.