What was found
FIRE TEST FAILED ON FIRST TWO ATTEMPTS, PASSED ON SUBSEQUENT TEST, CHECKED WIRING FOR CARGO SMOKE DETECTION SYSTEM PER WDM 26-16-12P1. FOUND PIN IN CONNECTOR DM7317A PIN 5 LOOSE. REPAIRED PIN IAW SWPM 20-31-11P1. OPS TESTED FIRE & OVHT DETECTION SYSTEM PER AMM 26-10-00 P501. TESTED GOOD. NO MESSAGES.