What was found
FUSELAGE SKIN GOUGED BS 1320 + 1 INCH AND 4 INCHES BELOW S28R. REMOVED DAMAGE, NDT FOR METAL LOSS. FOUND TO BE OUT OF LIMITS. CUT OUT DAMAGE FABRICATED AND INSTALLED DOUBLER IAW SRM 53-00-01 REPAIR 2 TABLE V, SRM 51-40-0 2, SRM 53-00-01 REPAIR 2, NDT P4 51-00-10, AMM 25-50-07 NDT P6 51-00 -19 SRM 51-20-01.