As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
R2 CABIN DOOR DISARM HANDLE WILL NOT MATCH FLUSH WITH LARGER VENT HANDLE. THE DISARM HANDLE MUST BE PUSHED THE LAST INCH OF MOVEMENT AND IT IS VERY HARD TO DO SO. LUBED ARM/DISARM LEVEL MECHANISM ON R2 DOOR IAW EMB 170 MM 52-70-00. OPS CHECK GOOD.