What was found
LANDING GEAR HANDLE WOULD NOT MOVE FOR RETRACTION AFTER TAKEOFF. DECLARED EMERGENCY, RETURNED TO FIELD, LANDED WITHOUT INCIDENT. R & R DC POWER MODULE IN SPDA 1, SLOT 13 AND LANDING GEAR CONTROL LEVER. GEAR SWINGS, OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LANDING GEAR HANDLE WOULD NOT MOVE FOR RETRACTION AFTER TAKEOFF. DECLARED EMERGENCY, RETURNED TO FIELD, LANDED WITHOUT INCIDENT. R & R DC POWER MODULE IN SPDA 1, SLOT 13 AND LANDING GEAR CONTROL LEVER. GEAR SWINGS, OPS CHECK GOOD.