What was found
DURING ROUTINE INSPECTION AT CURRENT C CHECK, FOUND LOWER BULKHEAD WEB CRACKED 0.60 INCH LONG AT BS 2658, BETWEEN WL 260 AND 265 AND BETWEEN L/S LBL 25 AND LBL 30. CUT WAY CRACKED AREA. PERFORMED DYE CHECK INSPECTION OF CUT-OUT AREA PER SOPM 20-20-20. NO ADDITIONAL CRACKING FOUND. FABRICATED FILLER, REPAIR DOUBLER AND ANGLE. INSTALLED PER STANDARD SRM. REFINISHED PER SRM.