What was found
RT WING L/E FIXED UPPER PANEL WS426 CRACKED FROM THE L/E OF THE PANEL THROUGH TO THE FIRST RIVET HOLE. LOCATION IS 29" OUTBD OF INBD EDGE OF FIXED PANEL AT WS 426, 0.500" LONG. OUT OF LIMITS AS PER SRM 51-70-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT WING L/E FIXED UPPER PANEL WS426 CRACKED FROM THE L/E OF THE PANEL THROUGH TO THE FIRST RIVET HOLE. LOCATION IS 29" OUTBD OF INBD EDGE OF FIXED PANEL AT WS 426, 0.500" LONG. OUT OF LIMITS AS PER SRM 51-70-02.