What was found
DURING THE PRESENT C4 CHECK, NR 2 PYLON LT NAC STA 332 FRAME RIB WAS FOUND WITH A WEAR AROUND MOUNT BOLT HOLE, APPROX 0.035 INCH MATERIAL REMOVED. THE ORIGINAL THICKNESS OF THE RIB WAS REPORTED AT 0.080 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING THE PRESENT C4 CHECK, NR 2 PYLON LT NAC STA 332 FRAME RIB WAS FOUND WITH A WEAR AROUND MOUNT BOLT HOLE, APPROX 0.035 INCH MATERIAL REMOVED. THE ORIGINAL THICKNESS OF THE RIB WAS REPORTED AT 0.080 INCH.