What was found
APU FAULT MESSAGE ON EICAS. APU FAILED AT ENGINE START WHEN APU BLEED SELECTED. R & R APU SURGE BLEED VALVE, OPS CHECKED SATISFACTORY IAW AMM 49-53-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU FAULT MESSAGE ON EICAS. APU FAILED AT ENGINE START WHEN APU BLEED SELECTED. R & R APU SURGE BLEED VALVE, OPS CHECKED SATISFACTORY IAW AMM 49-53-01.