What was found
UPON LEVEL OFF AT FL 360, RT ENG COMPRESSOR STALLED 4 TIMES. NO EXCEEDANCES WERE NOTED. ACCOMPLISHED NR 2 ENG BORESCOPE INSPECTION IAW ECM ITEM NR 2016-098 STEPS 4-9, WITH NO SIGNIFICANT DISCREPANCIES NOTED. REFERENCE WO 012864 FOR DETAILS. ACCOMPLISHED STEPS 1 - 3 & 12-13 OF ECM 2016P-098, NO DEFECTS NOTED AT THIS TIME. R & R NR 2 ENG EVBC IAW AMM 75-31-01,PN 776555-7, SN A3222. PERFORMED LEAK CHECK, OPERATIONS CHECK & RIG IAW 75-31-01.L R & R NR 2 ENG FCU, PN 773333-21, SN F1485 IAW AMM 73-21-01, LEAK & OPERATIONS CHECK OK. R & R NR 2 ENG FUEL PUMP, PN 715001-49, SN 3224 IAW AMM 73-11-01. LEAK & OPERATIONS CHECKED OK.