What was found
REPEAT WRITE UP - RT FWD WINDOW HEAT EICAS MESSAGE. PERFORMED OPS CHECK IAW AMM 30-41-00 OPS CHECK GOOD NO DEFECTS NOTED, CHECK MAIN PINS FOR SPARES FA195, FC 192 CHECKED GOOD, CHECK WIRE CONNECTORS D2898A, AFT PIN 19 WIRE CHECK GOOD, CHECKED WIRE D2998B PIN 5 CHECK GOOD.