What was found
LT ENG FIRE LP2 STATUS MSG INTERMITTENT ON GRD. REMOVED AND REPLACED FIRE OVERHEAT CONTROL CARD ON LOOP 2 AND ALSO ON LOOP 1, P/N ON 6445-1, S/N OFF 8559 FOR LOOP 1 CARD, NO FAULTS MESSAGE PRESENT DMI REMAINS OPEN PER MX CONTROL FOR OBSERVATION. CRIMPED NEW TERMINAL ON TERMINAL C ONTO TS681 IAW SWPM 20-30-11. OPS CHECK NORMAL IAW AMM 26-11-00. TERMINAL P/N OFF: 322338, NSN.