As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RIGHT GENERATOR DRIVE EICAS MESSAGE. (<P>DUE TO ENGINE SHUTDOWN ANOMALY WITH RIGHT ENGINE SPAR VALVE STUCK IN THE OPEN POSITION EICAS MESSAGE PRODUCE IS SIMILAR TO FIRE T-HANDLE BEING PULLED PERFORMED FAIL P RESET IAW 26-11-00 MESSAGE CLEARED OPS CHECK NORMAL AFTER ENGINE RUN IAW AMM 71-00-00 REFERENCE ITEM M2. </P>)