What was found
DURING RIGHT ENG STARTUP, NO EGT RISE AFTER FUEL SELECTOR TO RUN. N2 REMAINED 25.2, FUEL CUTOFF. SWITCHED IGNITER FROM SINGLE TO BOTH, ENGINE START NORMAL, RT ENG IGNITER 2 STATUS. PERFORMED T/S AS PER FIM 74-00 FT 811, CLEARED FAULTS IN BOTH PIMUS. ALSO VERIFIED GND AND VOLTAGE AT BOTH IGN BOXES ON RT ENGINE AS PER WDM 74-31-21 IGN SCHEMATIC, NO ISSUES NOTED. LP 1109658 - M5: REMOVED AND REPLACED RT ENG NR 1 IGNITER, OPS CHECK GOOD IAW AMM 74-21-02. LP 1109659 - M6: REMOVED AND REPLACED RT ENG NR 2 IGNITER, OPS CHECK GOOD IAW AMM 74-21-02.