What was found
APU FAULT MESSAGE ON LOWER EICAS. PERFORMED APU CONTROL UNIT BITE TEST IAW AMM 49-61-05 - FAULT NO LONGER PRESENT. PERFORMED APU START IAW AMM 49-11-00 NO FAULTS NOTED. NOTE: PER MCC REQUEST - AN APU COLD SOAK START VERIFICATION DEFERRAL WAS OPENED (MDDR 117524) DDG 25-AP-01; (ETOPS PROGRAM)