What was found
APU FAULT, ATTEMPTED 3 STARTS WITH NO SUCCESS. APU DOOR STATUS MESSAGE APPEARED MOMENTARILY. PERFORMED APU OPERATIONAL TEST, OPS CHECK GOOD PER AMM 49-11-00. ALSO PERFORMED APU CONTROL UNIT BITE TEST, NO FAULTS NOTED AT THIS TIME.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU FAULT, ATTEMPTED 3 STARTS WITH NO SUCCESS. APU DOOR STATUS MESSAGE APPEARED MOMENTARILY. PERFORMED APU OPERATIONAL TEST, OPS CHECK GOOD PER AMM 49-11-00. ALSO PERFORMED APU CONTROL UNIT BITE TEST, NO FAULTS NOTED AT THIS TIME.