What was found
RIGHT PACK TEMP EICAS MESSAGE, RAN QRH PROCEDURE.(<P>PERFORMED FIM 21-51 F/T 803, FOUND RAM INLET ACT FAULT ON PACK CONTROLLER. PERFORMED FAULT RESET PER FIM AND FAULT CLEARED. SYSTEM OK; NO CURRENT FAULT DISPLAYED.</P>)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT PACK TEMP EICAS MESSAGE, RAN QRH PROCEDURE.(<P>PERFORMED FIM 21-51 F/T 803, FOUND RAM INLET ACT FAULT ON PACK CONTROLLER. PERFORMED FAULT RESET PER FIM AND FAULT CLEARED. SYSTEM OK; NO CURRENT FAULT DISPLAYED.</P>)