What was found
CRT L FUEL PUMP EICAS MSG AND PRESS LIGHT ILLUMINATED. ALSO L FUEL C/B OPEN.(<P>TRANSFER TO MDDR #126188, CAT C, DUE 03APR20. IAW MEL 28-22-02A MAINTENANCE ACTIONS C/W.</P><P>29MAR, LP 1231746, ITEM M5: PERFORMED PHASE CHECK OF L CENTER FUEL PUMP WIRING IAW AMM 28-22-00, FOUND NO DEFECTS. REMOVED AND REPLACED GFI K10697 IAW AMM 28-22-18, OPS CHECK GOOD. THIS CLEARS DMI 126188, PLACARD REMOVED. DPI: ZH 1436Z.</P>)