What was found
LT AOA OVERHEAD DISCRETE LIGHT INOP. ANGLE OF ATTACK SENSOR HEATER SYSTEMS, NOTIFY DISPATCH. TRANSFERRED TO MDDR 134506, IAW MEL 30-32-01 CAT C. REMOVED AND REPLACED LIGHT MODULE, IAW AMM 33-16-02, TEST DISPATCH NOTIFIED. REMOVED AND REPLACED DISCRETE WARNING DISPLAY MODULE, PER AMM 33-16-02. OPS CHECK GOOD. THIS CLEARS DMI 134506. MCC NOTIFIED. PLACARDS REMOVED.