What was found
APU WOULD NOT START AFTER LANDING. PERFORMED FIM TASK 49-11 FAULT TREE 958, NO DEFECTS NOTED. SERVICED APU OIL, IAW AMM 12-13-01. TO FULL W/ .5 QUART. PERFORMED GBVI OF EWIS, IAW AMM 20-60-04-102-001. PERFORMED OPERATIONS CHECK, IAW AMM 49-11-00. 3 GOOD STARTS AND NO DEFECTS NOTED. ALSO USE A WIDE PNEUMATIC & ELECTRICAL LOAD ON APU.