Service difficulty report · Connector · Boeing 767383

Difficulty date
January 30, 2021
Submitted
February 8, 2021
Operation
Air carrier
Aircraft
N1511A
Make and model
Boeing 767383
Aircraft serial
24318
Aircraft time
102,438 hours, 17,048 cycles
Part
Connector
Condition
Damaged
Location
Modulation Valve
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

#1 ENG. FAN AIR MODULATING VALVE (FAMV) WILL NOT MODULATE FROM OPEN(<P>TRANSFERRED TO DMI# 141691 PER MEL 36-12-02-01, CAT C, DUE 09FEB21. MCC NOTIFIED. PLACARDS INSTALLED. MX ACTION COMPLIED WITH. ER OPERATIONS BEYOND 120 MINUTES NOT AUTHORIZED. RESEATED & CLEANED PIN 2 AT D4156 AS PER SWPM 20-60-02. ACCOMPLISHED AIR SUPPLY BITE TEST AS PER MM 36-23-00, TEST PASSED. THIS CLEARS MDDR 141691. REMOVED PLACARD. T/I GTC 0709. REACTIVATED FAMV.