What was found
DURING CLIMB L ENG VIBE INDICATED FAN 4.1 AT 104.7 AT PEAK. HELD STEADY AT 3.8-3.6 ABOVE 104.7(<P>CREW REPORTED NO VIBRATIONS FELT, INDICATION ONLY. PERFORMED GVI OF ENG, AFT ACCELEROMETER AND MOUNTING BRACKET. NO DEFECTS NOTED. FOUND MAIN #1 BEARING ACCELEROMETER CONNECTOR D10994 LOOSE. CLEANED AND RESECURED PER FIM TASK 77-31 FT808 AND AMM 77-31-02. PERFORMED AMM BITE PER AMM 77-31-00<BR /></P><P>LP 1276157: PERF LH ENG IDLE RUN IAW AMM 71-00-00. ENG VIB READINGS 0.6-0.8. NO OTHER ENG RELATED ISSUES NOTED AT THIS TIME.</P>)