What was found
FWD CARGO LOWER DOOR CUTOUT FLOOR BEAM T-CHORD CORROSION AT STA 580. REMOVED CORROSION ON THE FWD CARGO FLOOR BEAM T-CHORD AT STA 580 ORIG. MAT. WAS .100 REMAINING MAT. IS .070 FOUND TO BE OUT OF LIMITS AFTER DAMAGE REMOVAL IAW B767 SRM 53-00-15 ASSET #00226622. FABRICATED NEW T-CHORD FLOOR BEAM IAW B767 DWG:D141005320 AND INSTALLED IAW B767 SRM 51-40-02.>)