What was found
FWD CARGO STA 560 RBL44 APPROX FLOOR BEAM T-CHORD CORRODED. REMOVED CORROSION AT FWD CARGO STA 560 RBL44 FLOOR BEAM T-CHORD. ORIG. MAT. WAS .100 REAINING MAT. IS .050 FOUND TO BE OUT OF LIMITS. REMOVED,FABRICATED, AND INSTALLED NEW T-CHORD PN:BAC1506-3123 7075T-T6511 IAW B767 SRM 51-40-02,51-40-05,53-00-15,51-20-01,AMM 51-24-22,DWG:D141005320</DIV>)