As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING DECENT "R AFT FUEL PUMP" EICAS ILLUMINATED. / PUMP TURNED OFF PER QRH(<P>REF FIM 28-22 FT 819 TO STEP 49 FIG 106, FOUND MOISTURE CONTAMINATION ON FUEL PRESSURE SWITCH. CLEANED CANNON PLUG, RESECURED, COULD NOT DUPLICATE FAULT ON GROUND. RAN FUEL PUMP R AFT FOR 10 MINS NO FAULTS NOTED.</P>)