What was found
CRACK NOTED ON RH WING LOWER SURFACE STR L-6.5 MOST I/B FASTENER AT 6 O'CLOCK POSITION LOOKING UP/FWD. APPROX 1/4" LONG.(<P>REPAIRED CRACK AT RH WING LOWER SURFACE STR L-6.5 MOST I/B FASTENER HOLE BTW WSTA 990.2 AND 1046.2 IAW B767 FAS EA 21069-P1 REV:IR, SRM 51-10-02, 51-40-02, 51-40-05, 51-20-01, AMM 51-24-22, 28-11-00, DWG:767-9470, AND EO: 6757A140 PT 4.</P>)