What was found
INTERMITTENT " R PACK TEMP" EICAS MESSAGE DURING ARRIVAL WITH "INOP" LIGHT IN PACK RESET SWITCH.(<P>TROUBLESHOT PER FIM 21-51 FAULT TREE 803. VERIFIED NO MESSAGE ON ECS PAGE. PERFORMED BITE ON RIGHT PACK TEMP CONTROLLER IAW B767 AMM 21-51-00-700-805-006. NO FAULTS NOTED. PERFORMED PACK TEMP CONTROL TEST IAW B767 AMM 21-51-00-700-810-006. OPS CHECK GOOD. NO DEFECTS NOTED. A/C OKAY FOR CONTINUED SERVICE.</P>)