What was found
R PACK AUTO FUNCTION INOP/INTERMITTENT.(<P>TRANSFERRED TO MDDR # 155732, MEL 21-51-03-01. CAT C. DUE ON 05NOV21. MCC: 0928Z D.L.</P> / <P>29OCT21 - LP 1394801 - ITEM# 7 - AFW - PERFORMED B767 FIM 21-51 FT. 870. FOUND COMPRESSOR SENSOR FAULT LIGHT ON. REMOVED & REPLACED COMPRESSOR OUTLET TEMP SENSOR IAW B767 AMM 21-52-01. LEAK & OPS CHECK GOOD. FAULT CLEARED. THIS CLEARD DMI 155732. MCC NOTIFIED. PLACARDS REMOVED.</P>)