What was found
L ENG FIRE LP 1 INTERMITTENTLY APPEARING ON STATUS PAGE. PERFORMED FIM 26-11 P/T 804 UP TO BLOCK 52. ALL RESISTANCE CHECKS WITHIN LIMITS PER TABLE A. UPON DOING THE RESISTANCE CHECKS FOUND LOOSE TERMINAL END ON LOWER & AFT FIRE DETECTOR TERMINAL TS45. RESECURED IAW 26-11-02 & WDM 26-11-11. OPS CHECK GOOD. PERF ENG RUN IAW AMM 71-00-00. NO MSG NOTED. PERF DVI & WIRE SHAKE DOWN OF LH ENG FIRE LP1 IAW AMM 20-60-03. NO DEFECTS NOTED AT THIS TIME. PERF ENGINE RUN IAW AMM 71-00-00. NO STATUS MSG DISPLAYED AT THIS TIME.