What was found
WHILE GIVING OK TO INSTALL AFT PIT BULKHEAD SUPPORTS, FOUND CORROSION ON BEAM AT STA 947.5, BETWEEN STR 24-26, WL 170 (LOWER FRAME) (REMOVED CORROSION ON INNER CHORD LOWER FRAME @STA. 947.5, STR. 24R-26R IN AREA OF 5.5"L X .8"W X .007"D. FOUND IN LIMITS PER SRM 53-00-07-1A-1, FIG 102)