What was found
***CORROSION***AREA AFT OF AFT CARGO COMPARTMENT, CORROSION ON FRAME, STA. 947, BETWEEN STRINGERS S19R - S21R (CORROSION FOUND IN AREAS 4.0"L X 2.0"WV@STR 19R-20R. 2.6"L X 2.3"W @STR. 20R-21R AND 8.0"L X .8"W ON INNER CHORD STR 20R-21R @STA. 947. CORROSION REWORK AREAS FOUND TO BE OUT OF LIMITS PER SRM 53-00-07-1A-1, TABLE 101. REPAIRED STA. 947 FRAME, STR. 19R-21R PER ER#22-02291 REV. IR)