What was found
DERIVED FROM EO 6734A200, ELECTRICAL WIRES ARE NOT INSTALLED ON CONNECTORS D4717J/P AND D4711J/P IAW WIRE DIAGRAM 34-53-11 AND 34-53-21. "STC ST02126LA"(<P>THE ELECTRICAL WIRES W9133-9903R/9904B-22 AND WAAS-9004-22R/WASS-9005-22B WERE RELOCATED TO CONNECTOR D4717P/J, THE ELECTICAL WIRES W9145-9903R/9904B-22 AND WAAS-9204-22R/WAAS-9205-22B WERE RELOCATED TO CONNECTOR D4711P/J AND THE WIRES W9133-9903R/9904B-22 AND W9145-9903R/9904B-22 WERE RENAMED. I.A.W. EA 6734A0007 REV 0 DATE 15 MAR 2023</P>)