What was found
UPPER LOBE INTERIOR STRUCTURE, ON BODY STA 1021, BETWEEN STR 19 AND 20 RH, A CORROSION L=0.5" W=0.5"(<P>UPPER LOBE INTERIOR STRUCTURE, ON BODY STA 1021, BETWEEN STR 19 AND 20 RH CORROSION LEVEL 1 WAS REWORKED, INSPECTED, EVALUATED AND WITHIN ALLOWABLE LIMITS IAW SRM 53-00-07-1A-1. FOUND PRIMER AND PAINT WAS RESTORED. NO FURTHER DEFECTS NOTED.</P>)