Service difficulty report · Actuator · Boeing 7673Y0

Difficulty date
March 24, 2025
Submitted
March 26, 2025
Operation
Air carrier
Aircraft
N642GT
Make and model
Boeing 7673Y0
Aircraft serial
26207
Aircraft time
86,972 hours, 25,154 cycles
Part
Actuator
Part number
251T360014
Condition
Leaking
Location
Zone 300
Stage of operation
LD
How discovered
O
Nature of condition
K, J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

VERTICAL STABILIZER WITH EVIDENCE OF HYDRAULIC LEAK IN SERVO VALVE.(<P>RUDDER RATIO CHANGER ACTUATOR WAS REPLACED I.A.W AMM 27-21-15-422-024 OPERATONAL TEST WAS PERFORMED AND NO LEAKS FOUND, TORQUE APPLIED 280 LB-IN, 360 LB-IN S/N 0823114404 DATE 12DEC2026.</P>)

More about the Boeing 767-3Y0