What was found
FOUND ONE DENT ON THE FUSELAGE SKIN RH SIDE BEHIND MLG WW ABOVE THE RAT HOUSING. GOUGE ON FUSELAGE SKIN STA 1153-1175 AT STR 29R IS OUT OF LIMITS IAW SRM 53-00-01-1A-1. ALLOWABLE DAMAGE 1 REV 131. PERFORMED SKIN REPAIR IAW SRM 53-00-01-2R-1 REPAIR 1 REV 131.<