Service difficulty report · Clamp · Boeing 74747UF

Difficulty date
June 30, 2026
Submitted
July 1, 2026
Operation
Air carrier
Aircraft
N499MC
Make and model
Boeing 74747UF
Aircraft serial
29260
Aircraft time
105,188 hours, 17,897 cycles
Part
Clamp
Part number
8085501
Part serial
200112114
Condition
Leaking
Location
Zone 100
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

EQUIPMENT COOLING EICAS MESSAGE IN FLIGHT. REPLACED FLIGHT DECK LOW FLOW DETECTOR & OPS CHECKED GOOD IAW AMM 21-58-02/201. REMOVED AND REPLACED FLIGHT DECK FLOW REGULATOR VALVE & OPS CHECKED GOOD IAW AMM 21-61-09/501. DURING TROUBLESHOOTING, FOUND FOD INSIDE COOLING DUCT. FOD REMOVED. FOUND FWD E/E COOLING FAN BOOT CLAMP LEAKING AIR. RESECURED CLAMP & LEAK CHECKED GOOD IAW AMM 21-58-01. PERFORMED GROUND TEST OF E/E COOLING SYSTEM & OPS CHECKED GOOD IAW AMM 21-58-02/201.