What was found
INSPECTION TYPE:N/A, CREW REPORTED T/E FLAP DISAGREE EICAS MSG ON APPROACH AND FLAPS DID NOT EXTEND WHEN COMMANDED. FOUND NR 3 FLAP TRANS FLUID LOW AND NR 1 FLAP TRANS OVERLOAD IND POPPED. AS-E ACCOMPLISHED. REMOVED AND REPLACED NR 1 FLAP TRANS, OPS CK GOOD.