What was found
INSPECTION TYPE:N/A NOSE LANDING GEAR TOOK 4 CYCLES TO EXTEND MANUAL EXTENSION WAS NO HE LP. *S/D* REF WDM 32-64-01 REMOVED AND REPLACED WIRE BETWEEN S96 & S93. REMOVED AND ADJUSTED CORRECTLY. REMOVED AND REPLACED NLG LOCK ACT W/REF 32-33-11, PERFORMED NLG MANUAL EXT W/REF 32-34-00. REMOVED AND REPLACED NLG LOCK SW W/REF MM 32-61-21, ALL ITEM R/R OPS CHECK AND LEAK CHECK GOOD. NLG SWING AND MANUAL EXTENSION NORMAL, OK TO CONTINUE.