What was found
INSPECTION TYPE:C FUSELAGE SKIN SHOW CRACK INDICATION BS 1080 STR 14R NDT FINDING MARKED RUNNING FORM FASTENER HOLE. VERIFICATION SKIN CRACK AT BS 1080 S14R IAW B727 NDT MANUAL PART 6 51-00-00 FIG 4, CUT OUT DAMAGE AREA AT BS 1080 STR 14R IAW B727 SRM 53-30-3 PERFORMED HFEC AROUND CUT OUT, FOUND NO CRACK NDT INSPECTION AS PER B727 PART 6 51-00-00 FIG 4. INSTALLED DOUBLER AND FILLER RE PAIR AT STA 1080 STR14 IAW SRM B727 53-30-3 FIG 14.