What was found
INSPECTION TYPE:C NR 2 ENG FWD BHD FOR ENG FRONT MOUNT ATTACH, THE I/B CHORD LOWER SECTION HAS A MINOR DENT MARK WHICH WAS PREVIOUSLY SMOOTHED OUT. NDT INSP FOUND THE THICKNESS OF THE CHORD WORN OUT 25% APPROX IT'S OUT OF SRM LIMIT 54-10-01 FIG 1. THE FWD ENGINE MOUNT ATTACHED BHD CHORD WAS REPLACED IAW SRM 51-10-01 PG 8. THE ENGINE FWD MOUNT FTGS ( I/B AND O/B ) WERE REFITTED PER MM 20-51-01 AND THE ANTI-ICING DUCT WAS REFITTED AND LEAK CHK CARRIED OUT PER MM 30-21-06.