What was found
INSPECTION TYPE:C+SI NOSE LANDING GEAR BAY, EVIDENCE OF CORROSION IN TORQUE BOX AREA. ARE A JUST AFT OF LT FWD NLG DOOR AT BS 288 LT. CORROSION REMOVED AND FOUND TO BE OUTSIDE LIMITS IAW SRM 51-10-1. OLD CHORD REMOVED IAW SRM 51-30-2 AND NEW CHORD DRILLED OFF IAW DWG 6 5-18415. NEW CHORD INSTALLED IAW DWG 65-18415 AND SRM 51-30-2. CRACK WAS THEN FOUND AT SKIN BS 350 LBL 18, NEW REPAIR INSTALLED IAW SRM 53-30-3.