What was found
INSPECTION TYPE:C RT SIDE W/W ON BS 300 VERTICAL BEAM WEB FOUND 1 EA INSULATION BLANKET STAND-OFF HOLE CRACKED AND JUST BETWEEN NR 1 & 2 STIFFENER. VERTICAL BEAM WEB REPLACED AS PER SRM 51-10-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C RT SIDE W/W ON BS 300 VERTICAL BEAM WEB FOUND 1 EA INSULATION BLANKET STAND-OFF HOLE CRACKED AND JUST BETWEEN NR 1 & 2 STIFFENER. VERTICAL BEAM WEB REPLACED AS PER SRM 51-10-01.