What was found
INSPECTION TYPE:C RT SIDE NOSE W/W ON BS 320 VERTICAL BEAM WEB FOUND 1 EA INSULATION BLANKET STAND OFF HOLE CRACKED AT JUST BETWEEN NR 1 AND 2 STIFFENER. VERTICAL BEAM WEB REPLACED AS PER SRM 51-10-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C RT SIDE NOSE W/W ON BS 320 VERTICAL BEAM WEB FOUND 1 EA INSULATION BLANKET STAND OFF HOLE CRACKED AT JUST BETWEEN NR 1 AND 2 STIFFENER. VERTICAL BEAM WEB REPLACED AS PER SRM 51-10-01.