What was found
CRACK IN STEEL STRAP UNDER R/T ADF PNL. MILLED STEEL STRAP UNDER RT ADF (FWD) PANEL CRACKED AT STA 82.7 WHERE WING MEETS CENTER TANK BUT T L7ORT VERIFIED WITH EDDY CURRENT (SKI FITTING). R&R'D FITTING IAW DWG J060095 SRM 51-1-20D, 51-1-21,51-3-0 & 53-1-0. C/W WITH D244478.REF N/R 591533.