What was found
INSPECTION TYPE:C1 LEFT CENTER SERVICE DOOR BEAM SEGMENT ON DOOR IS CRACKED AT APPROX STA 1295 AT LONG 16L, 3RD LIGHTENING HOLE FROM TOP. CUT INTERCOSTAL/BEAM, FABRICATED AND INSTALLED BEAM SECTION IAW SRM 52-2-0 FIG 2, 52-40-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1 LEFT CENTER SERVICE DOOR BEAM SEGMENT ON DOOR IS CRACKED AT APPROX STA 1295 AT LONG 16L, 3RD LIGHTENING HOLE FROM TOP. CUT INTERCOSTAL/BEAM, FABRICATED AND INSTALLED BEAM SECTION IAW SRM 52-2-0 FIG 2, 52-40-01.